T6 Low-Speed Centrifuge: The Powerful Engine for High-Throughput Separation
◆ ◆ ◆
T6低速离心机——高通量分离的强力引擎
当实验室的处理量从几十支试管跃升至数百支采血管,当单次离心的容量需求从百毫升级攀升至升级别,常规离心机便力不从心了。渤程T6大容量低速离心机正是为应对这一挑战而生——它不仅继承了T5的全部核心功能,更以4×750ml的超大容量和独创的自动脱帽技术,将高通量分离的效率推向新高度。
When a laboratory's processing volume jumps from dozens of tubes to hundreds of blood collection tubes, when single-run capacity needs climb from the hundred-milliliter range to the liter level, conventional centrifuges simply cannot keep up. TheBio-Chem T6 Large-Capacity Low-Speed Centrifuge was built to meet this challenge head-on. Not only does it inherit all core functions of the T5, but it also pushes high-throughput separation efficiency to new heights with its ultra-large 4×750ml capacity and innovative automatic cap-removal technology.

核心优势详解
Core Advantages in Detail
全面继承T5功能:成熟可靠的基因
Full Inheritance of T5 Functions: A Proven, Reliable Foundation
T6并非简单的"放大版"离心机,而是在T5成熟平台上的全面升级。T5广受好评的功能在T6上全部保留:液晶触摸屏(支持戴手套操作)、无刷电机驱动、双锁安全系统、离心后自动开门、304不锈钢内腔、可调节加减速模式(防样本重悬浮)、九重安全保护系统。这意味着用户在获得更大容量的同时,无需在操控体验和安全保障上做任何妥协。
The T6 is not simply a "scaled-up" centrifuge—it is a comprehensive upgrade built on the T5's mature platform. All the features that have earned the T5 widespread acclaim are fully retained in the T6: LCD touchscreen (with glove-friendly operation), brushless motor drive, dual-lock safety system, auto-door-open after centrifugation, 304 stainless steel chamber, adjustable acceleration/deceleration profiles (to prevent sample resuspension), and the nine-layer safety protection system. This means users gain greater capacity without making any compromises in handling experience or safety assurance.
自动脱帽功能:一次离心,两步合一
Automatic Cap Removal: Two Steps Combined into One
这是T6最具突破性的功能。T6配备专用的自动脱帽方吊杯,可同时容纳4×37支真空采血管(即每批148支)。在离心减速阶段,方吊杯的特殊结构会自动将采血管的帽盖剥离。离心完成后,操作者直接取出的是已经脱帽的采血管——无需二次手动脱帽,大幅节省了人力时间成本。
This is the T6's most groundbreaking feature. The T6 is equipped with specialized automatic cap-removal square buckets that can simultaneously hold 4×37 vacuum blood collection tubes (148 tubes per batch). During the deceleration phase of centrifugation, the unique structure of the square buckets automatically strips the caps from the blood tubes. When the operator opens the centrifuge after the run, they find the blood tubes already decapped—eliminating the need for a separate manual cap-removal step and dramatically reducing labor time and costs.
在临床检验中心或血液样本处理场景中,每天需要处理数百甚至上千支真空采血管。传统的"先离心、再手动脱帽"流程不仅耗时,还存在气溶胶暴露风险。T6的自动脱帽功能将两个步骤合二为一,效率提升立竿见影。
In clinical testing centers or blood sample processing facilities where hundreds or even thousands of vacuum blood tubes must be processed daily, the traditional "centrifuge first, then manually decap" workflow is not only time-consuming but also carries aerosol exposure risks. The T6's automatic cap-removal function merges these two steps into one, delivering an immediate and visible boost in efficiency.
大容量设计:4×750ml,从容应对
Large Capacity Design: 4×750ml for Demanding Workloads
T6的铝合金水平转子支持4×750ml的超大容量,配合1000W大功率电机,即使满载也能保持稳定运行。对于需要处理大体积样品的生物制药、血液制品研发等领域,这意味着更少的离心批次和更高的单位时间产出。
The T6's aluminum alloy swing-out rotor supports an ultra-large capacity of 4×750ml, and with its 1000W high-power motor, it maintains stable operation even under full load. For fields such as biopharmaceuticals and blood product development that require processing of large-volume samples, this means fewer centrifugation batches and higher throughput per unit of time.
酶标板与水平摆动桶并行使用:效率倍增
Simultaneous Microplate and Swing-Bucket Operation: Doubled Efficiency
T6支持酶标板吊篮和水平摆动桶同时安装使用。这一设计允许研究人员在同一批次中同时处理不同类型的样品——例如,在水平摆动桶中离心大容量培养液的同时,在酶标板吊篮中处理ELISA板。对于多任务并行的繁忙实验室,这一功能有效减少了等待时间,提高了设备利用率。
The T6 supports simultaneous installation and use of microplate carriers and swing buckets. This design allows researchers to process different types of samples in the same run—for example, centrifuging large-volume culture media in swing buckets while simultaneously processing ELISA plates in the microplate carriers. For busy laboratories running multiple tasks in parallel, this feature effectively reduces waiting time and maximizes equipment utilization.
方形与圆形摆动桶灵活适配:一个转子,无限可能
Flexible Square and Round Bucket Adaptation: One Rotor, Endless Possibilities
T6的转子系统支持方形和圆形两种摆动桶,并可适配各种转接器。方形摆动桶适合真空采血管等规则排列的样品,圆形摆动桶则更适合各类锥底离心管。用户可根据实际需求自由组合,无需更换转子即可切换样品类型,极大地提升了操作灵活性。
The T6's rotor system supports both square and round swing buckets, adaptable to various adapters. Square buckets are ideal for regularly arranged samples such as vacuum blood tubes, while round buckets are better suited for various conical-bottom centrifuge tubes. Users can freely combine configurations based on actual needs—switching sample types without changing rotors greatly enhances operational flexibility.
技术参数
Technical Specifications
参数 | 规格 |
最大容量 | 4×750ml(水平转子) |
最高转速 | 6000 rpm |
最大离心力 | 6842×g |
转速精度 | ±10 rpm |
定时范围 | 0-99min59s |
软刹车 | 9档 |
噪音 | ≤65 dB(A) |
功率 | 1000W |
尺寸 | 600×465×335 mm |
重量 | 52 kg |
Parameter | Specification |
Maximum Capacity | 4×750ml (swing-out rotor) |
Maximum Speed | 6000 rpm |
Maximum RCF | 6842×g |
Speed Accuracy | ±10 rpm |
Timer Range | 0-99min59s |
Soft Braking | 9 levels |
Noise Level | ≤65 dB(A) |
Power | 1000W |
Dimensions | 600×465×335 mm |
Weight | 52 kg |

转子配置详解
Rotor Configuration in Detail
T6的转子系统在大容量的基础上兼顾了多样性,能够胜任从高通量采血管处理到大规模样品分离的全谱系任务:
The T6's rotor system balances diversity with large capacity, capable of handling the full spectrum of tasks from high-throughput blood tube processing to large-scale sample separation:
转子类型 | 容量 | 最高转速 | 最大离心力 |
钣金角转子 | 4×250ml | 6000 rpm | 6842×g |
铝合金水平转子 | 4×750ml | 4000 rpm | 3479×g |
自动脱帽方吊杯 | 4×37支真空采血管 | 4000 rpm | — |
酶标板吊篮 | 4×2×96孔 | 4000 rpm | — |
铝合金圆吊杯 | 750ml | 4000 rpm | 3835×g |
Rotor Type | Capacity | Max Speed | Max RCF |
Sheet Metal Fixed-Angle Rotor | 4×250ml | 6000 rpm | 6842×g |
Aluminum Alloy Swing-Out Rotor | 4×750ml | 4000 rpm | 3479×g |
Auto Cap-Removal Square Buckets | 4×37 vacuum blood tubes | 4000 rpm | — |
Microplate Carriers | 4×2×96-well | 4000 rpm | — |
Aluminum Alloy Round Buckets | 750ml | 4000 rpm | 3835×g |
丰富的尼龙适配器选件进一步扩展了T6的兼容性:
An extensive selection of nylon adapters further expands the T6's compatibility:
-大容量适配器:500ml、250ml离心瓶适配器
Large-Capacity Adapters: For 500ml and 250ml centrifuge bottles
-多管位适配器:28×50ml、56×15ml、20×50ml、60×15ml
Multi-Tube Adapters: 28×50ml, 56×15ml, 20×50ml, 60×15ml configurations
-真空采血管适配器:与自动脱帽方吊杯配合,兼容主流品牌采血管规格
Vacuum Blood Tube Adapters: Designed to work with the auto cap-removal square buckets, compatible with major blood tube brands

应用场景:生物制药公司大规模血液样本处理
Application Scenario: Large-Scale Blood Sample Processing at a Biopharmaceutical Company
在某生物制药企业的质量控制部门,每天需要处理来自多个生产批次的大规模血液样本。样本量大、时效要求高、操作规范性严格——这对离心设备提出了极高的要求。
In the quality control department of a biopharmaceutical company, large-scale blood samples from multiple production batches must be processed daily. The sample volumes are large, turnaround time requirements are stringent, and operational compliance is strictly enforced—placing extremely high demands on centrifuge equipment.
引入T6后,该部门的工作流程发生了显著变化。此前使用多台普通离心机,每台每批仅能处理约40支采血管,脱帽完全依赖人工,耗时且存在生物安全风险。更换T6后,单台设备每批可处理148支采血管,且自动脱帽功能将后续处理时间缩短了近70%。操作人员从重复性的脱帽工作中解放出来,转而专注于质量检测本身。
After introducing the T6, the department's workflow underwent a significant transformation. Previously using multiple conventional centrifuges, each processing only about 40 blood tubes per batch with entirely manual cap removal—time-consuming and carrying biosafety risks. After switching to the T6, a single unit processes 148 tubes per batch, and the automatic cap-removal function reduced subsequent processing time by nearly 70%. Operators were freed from repetitive decapping work and could redirect their attention to quality testing itself.
此外,T6的大容量水平转子在血浆分离纯化环节也发挥了关键作用。4×750ml的容量意味着每批可处理3升样品,大幅减少了批次间差异,提高了产品一致性。
Additionally, the T6's large-capacity swing-out rotor played a key role in plasma separation and purification. The 4×750ml capacity means 3 liters of sample can be processed per batch, significantly reducing batch-to-batch variation and improving product consistency.
使用案例:高通量真空采血管处理工作流
Use Case: High-Throughput Vacuum Blood Tube Processing Workflow
以下是使用T6自动脱帽功能进行高通量真空采血管处理的完整工作流:
The following is the complete workflow for high-throughput vacuum blood tube processing using the T6's automatic cap-removal function:
装载采血管
Step 1: Load Blood Tubes
将采血管按规格装入自动脱帽方吊杯。每个方吊杯可容纳37支真空采血管,4个吊杯共计148支/批。确保采血管帽朝上、排列整齐,方吊杯盖板正确安装。
Load the blood tubes into the automatic cap-removal square buckets according to specifications. Each square bucket accommodates 37 vacuum blood tubes, with 4 buckets totaling 148 tubes per batch. Ensure all tube caps are facing upward, tubes are neatly arranged, and the bucket cover plates are properly installed.
设置离心参数
Step 2: Set Centrifugation Parameters
在触摸屏上设置离心参数:转速(如4000 rpm)、离心时间(如10min),并选择适当的加减速档位。自动脱帽功能依赖减速阶段的力学作用,建议使用中等减速档位(如5-6档)以确保脱帽效果。
On the touchscreen, set centrifugation parameters: speed (e.g., 4000 rpm), centrifugation time (e.g., 10 min), and select appropriate acceleration/deceleration levels. The automatic cap-removal function relies on deceleration forces—a moderate deceleration level (such as 5-6) is recommended to ensure effective cap removal.
启动离心
Step 3: Start Centrifugation
确认门盖锁紧后启动程序。T6的无刷电机平稳加速至设定转速,运行过程中实时显示各项参数。
After confirming the lid is securely locked, start the program. The T6's brushless motor smoothly accelerates to the set speed, with all parameters displayed in real time during operation.
减速阶段自动脱帽
Step 4: Automatic Cap Removal During Deceleration
离心结束后进入减速阶段,方吊杯的特殊结构在减速力作用下自动将采血管帽盖剥离。这一过程无需人工干预,完全集成在离心周期内。
After centrifugation ends, the deceleration phase begins. The special structure of the square buckets automatically strips the blood tube caps under deceleration forces. This process requires no manual intervention and is fully integrated into the centrifugation cycle.
离心结束,门锁自动打开
Step 5: Centrifugation Complete, Door Auto-Opens
减速完成并停止后,门锁自动释放。操作者打开门盖即可看到已完成脱帽的采血管。
After deceleration is complete and the rotor has stopped, the door lock automatically releases. The operator opens the lid to find the blood tubes already decapped.
取出采血管,收集分离样品
Step 6: Remove Tubes and Collect Separated Samples
直接取出已脱帽的采血管,用移液器或自动分液系统收集分离后的血清/血浆层。无需手动拔帽,既节省了时间,也降低了气溶胶暴露风险。
Directly remove the decapped blood tubes and use a pipette or automated liquid handling system to collect the separated serum/plasma layer. No manual cap pulling is needed—saving time and reducing aerosol exposure risk.
T6 vs T5:何时升级到T6?
T6 vs T5: When to Upgrade to the T6?
T5和T6同为渤程低速离心机系列的优秀产品,选择哪一款取决于实验室的实际需求:
Both the T5 and T6 are outstanding products in Bio-Chem's low-speed centrifuge series. The choice depends on your laboratory's actual needs:
对比维度 | T5 | T6 |
最大容量 | 4×500ml | 4×750ml |
最大离心力 | 5353×g | 6842×g |
功率 | 600W | 1000W |
重量 | 35kg | 52kg |
噪音 | ≤58 dB(A) | ≤65 dB(A) |
自动脱帽 | 不支持 | 支持(4×37支/批) |
酶标板与摆动桶并行 | 不支持 | 支持 |
适合场景 | 中小型实验室多任务处理 | 大规模高通量样品处理 |
Comparison | T5 | T6 |
Max Capacity | 4×500ml | 4×750ml |
Max RCF | 5353×g | 6842×g |
Power | 600W | 1000W |
Weight | 35kg | 52kg |
Noise | ≤58 dB(A) | ≤65 dB(A) |
Auto Cap Removal | Not supported | Supported (4×37 tubes/batch) |
Microplate + Buckets Parallel | Not supported | Supported |
Ideal For | Small-to-mid lab multi-tasking | Large-scale high-throughput processing |
建议在以下情况升级至T6:
We recommend upgrading to the T6 when:
1.日处理采血管量超过200支:T6的自动脱帽功能将显著降低人力成本
Daily blood tube processing exceeds 200 tubes: The T6's automatic cap removal will significantly reduce labor costs
2.次离心容量需求超过500ml×4:T6的750ml×4水平转子提供更大吞吐量
Single-run capacity needs exceed 500ml×4: The T6's 750ml×4 swing-out rotor provides greater throughput
3.需要同时处理不同类型样品:T6支持酶标板与摆动桶并行,减少等待时间
You need to process different sample types simultaneously: The T6 supports parallel microplate and swing-bucket operation, reducing wait time
4.从事生物制药或血液制品生产:T6的大容量和高通量特性更契合生产环境需求
You work in biopharmaceutical or blood product manufacturing: The T6's large capacity and high-throughput capabilities better suit production environments
反之,如果您的实验室:
Conversely, if your laboratory:
- 离心任务以中小容量为主(≤500ml×4)
Primarily handles small-to-medium volumes (≤500ml×4)
- 采血管处理量不大,手动脱帽可接受
Has modest blood tube processing needs where manual decapping is acceptable
- 实验台空间有限(T5尺寸更紧凑)
Has limited bench space (the T5 is more compact)
- 对噪音敏感(T5的58dB更安静)
Is sensitive to noise (the T5's 58 dB is quieter)
那么T5仍然是更具性价比的选择。
Then the T5 remains the more cost-effective choice.
两款产品共享相同的安全理念和操控逻辑,无论选择哪一款,渤程都为您提供的是经过严格验证的可靠工具。T6不是对T5的替代,而是在高通量场景下的有力补充——选择适合的,才是最好的。
Both products share the same safety philosophy and operating logic. Whether you choose either one, Bio-Chem provides you with a rigorously validated, reliable tool. The T6 is not a replacement for the T5—it is a powerful complement for high-throughput scenarios. Choosing the right tool for your needs is always the best decision.
◆ ◆ ◆